Protocols ·
PET/CT Reconstruction Parameters: Acquisition and Recon Choices That Matter
How time per bed, the attenuation-correction CT, OSEM, PSF, TOF, filters and matrix change PET/CT images and SUVs, and how to keep protocols consistent.
TECHNOLOGIST HUB
Practical knowledge for imaging technologists, wherever you scan.
Protocols ·
How time per bed, the attenuation-correction CT, OSEM, PSF, TOF, filters and matrix change PET/CT images and SUVs, and how to keep protocols consistent.
Image Quality ·
How to cut metal artifact in MRI at the console: sequence choice, bandwidth, slice thickness, fat suppression, and when to use VAT, SEMAC or MAVRIC.
New Technology ·
Which dual-energy CT outputs show what, which exams they earn a place in, and how to build them into protocols your whole team runs the same way.
Protocols ·
How bandwidth, matrix and averages trade MRI SNR against resolution and scan time, and how to standardize them across a mixed fleet.
New Technology ·
SWI shows veins, microbleeds and calcium that other sequences miss. Here is how it is built, how to set it up and how to read the phase image.
Positioning ·
The CC and MLO positioning mistakes we see most in training, from a fixed 45° angle to a lost inframammary fold, and how to fix them at the unit.
Image Quality ·
How CT reconstruction kernels trade sharpness for noise, which kernel to use for soft tissue, bone and lung, and how to build them into your protocols.
Protocols ·
How to choose diffusion b-values for brain, liver, prostate and breast MRI, build them on the scanner and keep ADC consistent across your fleet.
Protocols ·
How CHESS, SPAIR, STIR, water excitation and Dixon suppress fat, where each one fails, and what to check at the scanner.
Industry News ·
Imaging Diversified was a proud sponsor of the free Everything MRI Safety Forum 2026, held live on Zoom on November 3. Next up: meet us at RSNA 2026.
New Technology ·
How ASiR-V and deep learning reconstruction really work at the GE CT console, why turning them on does not lower dose, and the setup mistakes to avoid.
Positioning ·
Off-center patients get noisier images and the wrong mA. How table height, the scout and the bowtie filter interact, and how to center right.
Image Quality ·
Motion ruins good MRI sequences and eats table time. Here is a practical scanner-side checklist for preventing it and for recovering when it shows up.